If you work with 3D printed light-cured parts—whether for prototypes, modelli medici, or jewelry—understanding surface roughness is critical to meeting quality and functional needs. Light-cured 3D printing (like SLA and DLP) is known for high detail, but its surface roughness can vary widely from Ra 0.5 μm a RA 5 µm depending on key factors. This guide breaks down typical roughness ranges, core influencing factors, practical application standards, and actionable tips to improve surface quality.
1. Typical Roughness Ranges for 3D Printed Light-Cured Surfaces
Light-cured 3D printing (SLA and DLP) produces smoother surfaces than many other technologies (PER ESEMPIO., FDM), but the exact roughness depends on technology type, parametri, e materiali. Below is a detailed breakdown of standard ranges:
Tipo di tecnologia | Typical Roughness (Ra) | Optimal Roughness (With Optimization) | Key Advantages for Surface Quality |
SLA (Stereolithic) | 1 µm ~ 3 µm | < 1 µm | High laser precision, linee di strato minime |
Dlp (Elaborazione della luce digitale) | 1 µm ~ 5 µm | ~ 1 µm (High-Resolution DLP) | Stampa rapida; 4K projectors narrow roughness gaps with SLA |
General-Purpose Resin (Any Tech) | 2 µm ~ 5 µm | 1 µm ~ 2 µm (With Post-Processing) | Economico; suitable for non-critical prototypes |
High-Precision Resin (PER ESEMPIO., Dentale) | < 1 µm | 0.5 µm ~ 1 µm (With Fine Tuning) | Basso restringimento; ideal for medical or jewelry parts |
Nota: Ra (Average Surface Roughness) is the most common metric—lower values mean smoother surfaces. Per riferimento, a polished metal surface has an Ra of ~0.02 μm, while a standard light-cured part (senza post-elaborazione) falls between 1 µm ~ 3 µm.
2. 4 Core Factors That Impact Light-Cured Surface Roughness
Surface roughness isn’t random—it’s shaped by controllable factors. Understanding these lets you adjust parameters to achieve your desired smoothness. Below is a breakdown with specific examples and data:
(1) Tecnologia di stampa & Equipment Precision
The type of light-curing technology and device resolution directly affect surface quality:
- SLA: Uses a focused UV laser to cure resin layer by layer. Industrial-grade SLA machines (PER ESEMPIO., Stratasys) have laser spot sizes as small as 0.02 mm, producing surfaces with Ra < 1 µm. Consumer-grade SLA machines may have larger spots (0.05 mm ~ 0.1 mm), leading to Ra 2 µm ~ 3 µm.
- Dlp: Uses a projector to cure entire layers at once. Resolution matters here—4K DLP projectors (with smaller pixel sizes) can reach Ra ~ 1 µm, while 1080p projectors may result in Ra 3 µm ~ 5 μm due to visible pixel edges.
(2) Parametri di stampa
Even with the right equipment, poor parameter settings can ruin surface smoothness. The two most critical parameters are:
Spessore dello strato
Thinner layers mean fewer visible layer lines, but overly thin layers can cause resin flow issues. Here’s how layer thickness impacts roughness:
Spessore dello strato | Typical Roughness (Ra) | Note |
0.025 mm | 0.5 µm ~ 1 µm | Ideal for high-detail parts (PER ESEMPIO., gioielli) |
0.05 mm | 1 µm ~ 2 µm | Balances smoothness and print speed |
0.1 mm | 2 µm ~ 3 µm | Stampa rapida; linee di strato visibili |
> 0.1 mm | 3 µm ~ 5 µm | Only for rough prototypes |
Tempo di esposizione
- Insufficient exposure: Resin doesn’t cure fully, leaving sticky, superfici irregolari (Ra can jump to 4 µm ~ 6 µm).
- Overexposure: Resin shrinks excessively, causing warping or surface cracks (Ra increases by 1 µm ~ 2 µm).
Best practice: Follow the resin manufacturer’s recommended exposure time (PER ESEMPIO., 5 seconds per layer for standard resin).
(3) Resin Material Properties
Not all resins are equal—formulation affects shrinkage and surface finish:
- Restringimento: Most resins shrink 2% ~ 8% durante la cura. High-shrinkage resins (PER ESEMPIO., general-purpose resin) pull the surface unevenly, leading to Ra 2 µm ~ 5 µm. Low-shrinkage resins (PER ESEMPIO., resina specifica per i denti) shrink < 2%, producing Ra < 1 µm.
- Tipo di resina:
- General-purpose resin: Ra 2 µm ~ 5 µm; affordable but rough.
- High-precision resin (PER ESEMPIO., for medical models): Ra < 1 µm; formulated for minimal shrinkage.
- Flexible resin: Slightly higher roughness (Ra 1.5 µm ~ 3 µm) due to elastic properties.
(4) Post-Processing Processes
Post-processing is the final step to refine surface roughness—even a rough printed part can become smooth with the right treatments:
Passaggio di post-elaborazione | Roughness Reduction (Ra) | Gamma di costi (RMB/Piece) | Meglio per |
Simple Cleaning (Isopropyl Alcohol) | 0.5 µm ~ 1 µm | 5 ~ 10 | Removes uncured resin; Solanza di base |
Levigatura (1200 ~ 2000 Grit Sandpaper) | 2 µm ~ 4 µm | 20 ~ 50 | Eliminates layer lines; Ra drops from 5 μm a < 1 µm |
Lucidare (Pasta di lucidatura) | 0.3 µm ~ 0.5 µm | 30 ~ 80 | Mirror-like finish; ideal for jewelry |
Polimerizzazione UV secondaria | 0.2 µm ~ 0.5 µm | 10 ~ 30 | Reduces stickiness; improves surface uniformity |
Spruzzatura (Clear Coat) | 0.5 µm ~ 1 µm | 40 ~ 100 | Fills micropores; adds protection |
3. Surface Roughness Standards for Practical Applications
Different use cases require different levels of smoothness. Below are common applications and their recommended roughness:
Tipo di applicazione | Required Roughness (Ra) | Post-Processing Needed? | Ragionamento chiave |
Prototipi di base (PER ESEMPIO., part fit checks) | 2 µm ~ 5 µm | NO | Smoothness isn’t critical; saves time/cost |
Parti estetiche (PER ESEMPIO., custom figurines) | 1 µm ~ 2 µm | SÌ (Levigatura + Lucidare) | Visible surface quality matters |
Modelli medici (PER ESEMPIO., corone dentali) | 0.5 µm ~ 1 µm | SÌ (High-Precision Polishing) | Prevents bacterial growth; ensures biocompatibility |
Gioielli (PER ESEMPIO., pendenti) | < 1 µm | SÌ (Lucidare + Clear Coat) | Mirror finish enhances appearance |
Parti funzionali (PER ESEMPIO., piccoli ingranaggi) | 1 µm ~ 2 µm | SÌ (Levigatura) | Riduce l'attrito; improves part longevity |
4. 5 Step-by-Step Tips to Improve Light-Cured Surface Roughness
If your parts are too rough, follow these actionable steps to optimize smoothness:
- Scegli la tecnologia giusta: Use industrial-grade SLA or 4K DLP for Ra < 1 µm; avoid low-resolution DLP machines for high-detail parts.
- Set thin, but not too thin, strati: Inizia con 0.05 strati mm (balances smoothness and speed); utilizzo 0.025 mm for critical parts.
- Select low-shrinkage resin: Opt for dental or high-precision resin instead of general-purpose resin to reduce surface warping.
- Master exposure time: Test 3–5 exposure times (PER ESEMPIO., 4S, 5S, 6S) to find the sweet spot—avoid under/overexposure.
- Invest in post-processing: For Ra < 1 µm, sand with 1200 carta vetrata a grana, then polish with a microfiber cloth and polishing paste.
Yigu Technology’s Perspective on Light-Cured Surface Roughness
Alla tecnologia Yigu, Crediamo balance between precision, costo, and application needs is key to managing light-cured surface roughness. Many clients overspend on ultra-thin layers or expensive post-processing when their parts don’t require it—for example, usando 0.025 mm layers for basic prototypes (unnecessary for Ra 2 µm ~ 5 µm). Our team helps clients match parameters to their use case: for dental models, we recommend industrial SLA + low-shrinkage resin + high-precision polishing (achieves Ra 0.5 µm ~ 1 µm); per prototipi, we suggest 0.1 strati mm + nessuna post-elaborazione (salva 30% ~ 50% of time/cost). We also provide resin testing kits to let clients compare shrinkage and roughness before full-scale production—ensuring they get the right smoothness without overpaying.
Domande frequenti
- Can DLP ever be smoother than SLA for light-cured parts?
Yes—high-resolution 4K DLP machines (with pixel sizes < 0.01 mm) can reach Ra ~ 1 µm, matching mid-grade SLA machines. Tuttavia, industrial-grade SLA (with smaller laser spots) still outperforms DLP for ultra-smooth surfaces (Ra < 1 µm).
- Why does overly thin layer thickness (PER ESEMPIO., < 0.02 mm) increase roughness?
Thinner layers require more frequent resin refilling, which can cause uneven resin levels across the build plate. This leads to inconsistent curing and visible surface defects, pushing Ra up by 1 µm ~ 2 μm compared to 0.025 strati mm.
- How much does post-processing (levigatura + lucidare) reduce roughness?
For a part with initial Ra 5 µm (da 0.1 strati mm + general resin), sanding with 1200 grit sandpaper can drop Ra to 1 µm ~ 2 µm. Adding polishing paste further reduces it to < 1 μm—total roughness reduction of 80% ~ 90%.